EasyManua.ls Logo

Panasonic FP-XH Series

Panasonic FP-XH Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Offset
address
Name Default Description R W
-8,388,608 to +8,388,607
0008
Dwell
time
K0
Stores the setting of dwell time.
Setting range: 0 to 32,767ms
0009
Reserved for
system
- - - -
(Note 1) The offset addresses in the above table are for the table no. 0. They vary according to the table
numbers as described on the next page.
Offset addresses
Table no.
Control
code
Control
pattern
Positioning
acceleration
time
Positioning
deceleration
time
Positioning
target speed
Positioning
movement
amount
Dwell
time
1 0 1 2 3 4-5 6-7 8
2 10 11 12 13 14-15 16-17 18
3 20 21 22 23 24-25 26-27 28
4 30 31 32 33 34-35 36-37 38
5 40 41 42 43 44-45 46-47 48
6 50 51 52 53 54-55 56-57 58
7 60 61 62 63 64-65 66-67 68
8 70 71 72 73 74-75 76-77 78
9 80 81 82 83 84-85 86-87 88
10 90 91 92 93 94-95 96-97 98
11 100 101 102 103 104-105 106-107 108
12 110 111 112 113 114-115 116-117 118
13 120 121 122 123 124-125 126-127 128
14 130 131 132 133 134-135 136-137 138
15 140 141 142 143 144-145 146-147 148
16 150 151 152 153 154-155 156-157 158
17 160 161 162 163 164-165 166-167 168
18 170 171 172 173 174-175 176-177 178
19 180 181 182 183 184-185 186-187 188
20 190 191 192 193 194-195 196-197 198
(Note 1) For the positioning target speed and positioning movement amount, specify the lower address number
of 2-word area.
11.3 Positioning Memory
11-18 WUME-FPXHPOSG-01

Table of Contents