2. Make necessary parameter settings according to the application and press the [OK] button.
The settings will be stored as part of positioning parameter data.
Parameters
Parameter name
Default
(unit)
Settings
Basic
Pulse output method Pulse/Sign Pulse/Sign, CW/CCW
Pulse output rotation
direction
CW direction +
When selecting Pulse/Sign mode:
CW direction +: Select this setting for the case that the
elapsed value is increased when Sign output turns off.
CCW direction +: Select this setting for the case that the
elapsed value is increased when Sign output turns on.
When selecting CW/CCW mode:
CW direction +: Select this setting for the case that the
elapsed value is increased at the time of CW output.
CCW direction +: Select this setting for the case that the
elapsed value is increased at the time of CCW output.
Startup speed 100 (pps)
Set the startup speed common to each operation. This
setting is common to JOG operation, home return, E-point
control, P-point control, C-point control and J-point
control.
Setting range: 1 to 100,000
Positioning repeat count 0
Specify this setting for performing repetitive controls when
using E-point/P-point/C-point control.
4.2 Settings in Configurator PMX
4-10 WUME-FPXHPOSG-01