Settings
Item Setting example
Axis setting area
Startup speed 1,000 Hz
JOG operation
acceleration time
100 ms
JOG operation
deceleration time
200 ms
JOG operation target
speed
20,000 Hz
■
Configurator PMX settings
■
Sample program
The execution condition is set to be always executed. For details of instructions, refer to
"7 Instruction References".
CH No.0
JOG reverse operation starts.
CH No.0
JOG forward operation starts.
K0F381 JOGST K0
R4
K0F381 JOGST K1
R3
■
Operation at over limit input
Conditions Direction Limit status Operation
At startup
Forward
Over limit input (+): ON Not executable, Error occurs.
Over limit input (-): ON Executable
Reverse
Over limit input (+): ON Executable
Over limit input (-): ON Not executable, Error occurs.
During
operation
Forward
Over limit input (+): ON
Limit stops, Error occurs.
(Note 1)
Over limit input (-): ON
Limit stops, Error occurs.
(Note 1)
Reverse
Over limit input (+): ON
Limit stops, Error occurs.
(Note 1)
5.2 JOG Operation