Value Range
-39– -6 dB
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
CNG Signal Effective Detection Width 1 (ON)
Specifies the length of time that the PBX detects the CNG signal.
Value Range
20–5000 ms
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
CNG Signal Effective Detection Width 2 (OFF)
Specifies the length of time that the PBX waits until another CNG signal is detected.
Value Range
20–5000 ms
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
CNG Signal Fixation Detection Counter
Specifies the number of times the CNG signal must be detected before the PBX proceeds the fax operation.
Value Range
1–3
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
CNG Signal Fixation Detection Pattern
Specifies the CNG signal pattern to be detected before the PBX proceeds the fax operation.
Value Range
OFF, ON
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site