24.4 UM Configuration—[5-4] System Parameters—Parameters—PBX Parameters— PBX
Environment—Extension Transfer Sequence (Up to 16 digits / [0-9 * # D R F T X , ;])
Feature Guide References
3.2.2.7 Call Transfer Status
Call Transfer Sequence (Other)
Specifies the Call Transfer Sequence used by the mailbox. Only specified if
Call Transfer Sequence
(Selection) is set to "Other".
Value Range
Enter a maximum of 16 characters consisting of 0–9, , # and special codes:
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause (default 1 s)
; : Dial Pause (default 3 s)
X: Extension Dialling
0–9, , #: Dial Code
Maintenance Console Location
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting—Mailbox Parameters
Feature Guide References
3.2.2.7 Call Transfer Status
No Answer Time (Selection/Other)
Specifies the length of time that the Unified Messaging system waits before handling unanswered calls to the
extension.
Note
When "System" is selected, the Unified Messaging system uses the time pre-programmed in 24.4 UM
Configuration[5-4] System ParametersParameters—Dialling Parameters/MSW Notification
Dialling Parameters—Call Transfer No Answer Time (10-60 s).
Value Range
System, Other (If "Other" is selected, specify 10–60 s)
Maintenance Console Location
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting—Mailbox Parameters
860 PC Programming Manual
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting

Table of Contents