Conductive mode set-up procedure (continued)
4. Examine the insertion. Is the hardware properly seated? Is the work piece deformed? Adjust the
insertion force accordingly and insert another fastener.
5. Once the hardware is properly inserted, start the production run.
Experienced personnel must test the Safety System at
the beginning of each work shift. See the Safety System
Test in this section of this manual.
Never attempt to test or demonstrate this machines Safety
System by placing any portion of your hand or body between
the Upper and Lower tools. Always use the test procedure
outlined in Step 3 of this manual.
Eye protection must be worn when operating this machine