EasyManua.ls Logo

Pitco SSHLV Series - Manual Operation of Drain and Return (Auto Filter Only)

Pitco SSHLV Series
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pitco SSHLV (ROV) Gas Fryers
6 Manual Operation of Drain and Return (Auto Filter Only)
1. To open and/or close drain or return oil from
filter pan manually, hold center filter button until
display changes to fryer control (can be done
with fryer on/off).
2. Pressing “L” key brings up the return mode,
Pressing “Yes” key activates the motor and
allows the pump to return oil from the filter pan
to the vat. The pump/motor will remain on until
you press “yes” key again to toggle off.
3. Pressing the “1” key brings up drain toggle
option- press “YES” to open drain drain will
remain open until “YES” key is pressed again to
toggle drain closed.
!
DANGER
!
Any and all spilled oil, water or other liquids that
occurs as a result of operation, cleaning,
maintenance or repair of this fryer should
immediately be cleaned and dried. Failure to do
so can create a slippery surface resulting in
falling/impact injury or death.
L22-392 R1 20