Pitco SSHLV (ROV) Gas Fryers
27 Replacing the Self-Cleaning Burner Solenoid
Prior to moving, testing, maintaining or repairing
your appliance, ensure it is emptied of all oil,
cool, disconnected from gas and all electrical
power. Failure to do so may result in property
damage, damage to your fryer, injury or death.
1. Remove the SCB flex tube fitting using a ½
inch open-ended wrench.
2. Remove the SCB valve inlet fitting using a ½
inch open-ended wrench.
3. Disconnect the terminals using needle-nose
pliers.
4. Remove the two (2) elbows using a ½ inch
open-ended wrench.
5.Follow steps 1 through 4 in reverse to reinstall
SCB valve.
Check for gas leaks after installation or servicing
of a gas fryer. Apply a leak detection solution to
all connections and joints to ensure there are no
bubbles or leaks. Failure to check for and correct
any leaks could lead to fire and/or explosion,
property damage, injury and death.
L22-392 Rev 1 57