Pitco SSHLV (ROV) Gas Fryers
8 Checking Resistance
8.1 Checking the Resistance of the Transformer
1. Disconnect all electrical power. Remove the
front panel (see “Removing the Controller
Front Panel Bezel” in Section 5.1).
2. Disconnect the secondary side terminals.
3. Connect the multimeter to the secondary
terminals and check the resistance.
Secondary Terminals
4. Disconnect the primary side terminals.
5. Connect the black lead of multimeter to the
primary terminal marked “5” and check the
resistance readings of taps in following
chart on page 24.
L22-392 R1 23