EasyManua.ls Logo

Pitco SSHLV Series - Replacing the Pump Relay and Circuit Breaker; Replacing the Circuit Breaker

Pitco SSHLV Series
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pitco SSHLV (ROV) Gas Fryers
24 Replacing the Pump Relay and Circuit Breaker
24.1 Replacing the Circuit Breaker
1. Disconnect the connections and power
supply cords from the filter pump.
2. Remove the pump box.
3. Remove the circuit breaker from the pump
box.
4. Remove all wires on the circuit breaker using
needle-nose pliers.
5. Squeeze the tabs on the circuit breaker and
push it out.
6. Reinstall the new circuit breaker by following
steps 1 through 5 in reverse.
L22-392 Rev 1 50

Table of Contents

Related product manuals