Pitco SSHLV (ROV) Gas Fryers
24 Replacing the Pump Relay and Circuit Breaker
24.1 Replacing the Circuit Breaker
1. Disconnect the connections and power
supply cords from the filter pump.
2. Remove the pump box.
3. Remove the circuit breaker from the pump
box.
4. Remove all wires on the circuit breaker using
needle-nose pliers.
5. Squeeze the tabs on the circuit breaker and
push it out.
6. Reinstall the new circuit breaker by following
steps 1 through 5 in reverse.
L22-392 Rev 1 50