Pitco SSHLV (ROV) Gas Fryers
26.3 Adjusting Manifold Gas Pressure
1. Check the manifold gas pressure with the
manometer and compare the reading to the
manifold gas pressure table.
Manifold Gas Pressure Table
NAT
LP
4.0” wc (1.0 kPa) (10.0 mbar) 10” wc (2.5 kPa) (25 mbar)
2. Insert a flathead screwdriver into the cap and
turn counter-clockwise to remove it.
3. Insert flathead screwdriver into the cap and
turn counter-clockwise to increase the gas
pressure or clockwise to decrease the gas
pressure.
4. When adjustment is complete:
a. Turn off the gas supply line.
b. Disconnect the manometer.
c. Remove the test fitting.
d. Reinstall the gas manifold plug.
e. Reconnect solid state thermostat.
g. Turn on gas supply line.
!
DANGER
!
Check for gas leaks after installation or servicing
of a gas fryer. Apply a leak detection solution to
all connections and joints to ensure there are no
bubbles or leaks. Failure to check for and correct
any leaks could lead to fire and/or explosion,
property damage, injury and death.
26.4 Adjusting Pilot Flame
1. Remove pilot adjustment cap with Philips
screwdriver.
2. Rotate adjuster clockwise to decrease and
counter-clockwise to increase pilot flame.
3. Replace adjustment cap.
L22-392 Rev 1 56

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco SSHLV Series and is the answer not in the manual?

Pitco SSHLV Series Specifications

General IconGeneral
BrandPitco
ModelSSHLV Series
CategoryFryer
LanguageEnglish

Related product manuals