EasyManuals Logo

Pitco SSHLV Series User Manual

Pitco SSHLV Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
Pitco SSHLV (ROV) Gas Fryers
18 Gas Conversion
!
DANGER
!
Only qualified service personnel may service or
convert this appliance to use a gas other than
that for which it was originally manufactured.
Improper conversion can lead to property
damage, injury or death.
1. Remove the pilot assembly. See Replacing
an Igniter/Pilot Assembly” in Section 11.
2. Remove the nut, which holds the pilot tube,
using a 1/2 inch open-ended wrench.
3. Replace bullet orifice with one provide in the
gas conversion kit.
4. Change the main burner orifice tips.
5. Change the SCB orifice tip.
6. Replace and adjust the gas valve regulator.
7. Adjust the burner manifold pressure. See
section 26.2 “Taking a manifold gas pressure
reading”.
Manifold Gas Pressure Table
NAT
LP
4.0” wc,(1.0 kPa) (10 mbar) 10” wc (2.5 kPa) (25 mbar)
8. Insert a flathead screwdriver into the cap and
turn counter-clockwise to remove it.
9. Insert flathead screwdriver into the cap and
turn counter-clockwise to increase the gas
pressure or clockwise to decrease the gas
pressure.
10. Place a sticker on the door indicating the
unit has been converted.
!
DANGER
!
Check for gas leaks after installation or servicing
of a gas fryer. Apply a leak detection solution to
all connections and joints to ensure there are no
bubbles or leaks. Failure to check for and correct
any leaks could lead to fire and/or explosion,
property damage, injury and death.
L22-392 Rev 1 40

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco SSHLV Series and is the answer not in the manual?

Pitco SSHLV Series Specifications

General IconGeneral
BrandPitco
ModelSSHLV Series
CategoryFryer
LanguageEnglish

Related product manuals