Pitco SSHLV (ROV) Gas Fryers
20 Replacing the Optional Flush Hose Assembly and Valve
DANGER
Prior to moving, testing, maintaining or repairing
your appliance, ensure it is emptied of all oil,
cool, disconnected from gas and all electrical
power. Failure to do so may result in property
damage, damage to your fryer, injury or death.
1. Remove the lower connection at the 3-way
return valve in the back of the unit using a
15/16 inch wrench.
2. Remove the male quick disconnect using a
15/16 inch wrench.
3. Unplug the proximity switch.
4. Remove two (2) screws holding the flush
hose assembly using a 5/16 socket.
5. Remove the flush hose assembly.
6. Remove the four (4) screws from the
magnets using a flathead screwdriver.
L22-392 Rev 1 42