Pitco SSHLV (ROV) Gas Fryers
12 Replacing Drain Valve with Actuator (Auto Filter Only)
DANGER
Prior to moving, testing, maintaining or repairing
any appliance, ensure it is emptied of all oil,
cool, disconnected from gas and all electrical
power. Failure to do so may result in property
damage, damage to your fryer, injury or death.
1. Pitco ROV fryer with automated filtration
uses a 24 VDC drain actuator for opening
/closing the drain for each pot.
2. On the far left unit remove rubber protection
on thread of retaining clamp screw. Remove
the 2 bolts holding drain elbow in place. Loosen
the retaining clamp holding the drain piping
together and remove the drain elbow.
3. Once the elbow is removed, a small amount
of oil will dip from drain, place a rag or paper
towel in drain.
4. Using a 3/32 inch T handle hex key, loosen
the mounting screws on the drain actuator.
Remove the access panel rear of unit, unplug
Molex connector for actuator. Once unplugged,
slide the actuator off.
5. Follow steps 1 through 4 in reverse order to
reinstall Actuator. Remember to remove the
rag or paper towels from the drain.
DANGER
Any and all spilled oil, water or other liquids that
occurs as a result of operation, cleaning,
maintenance or repair of this fryer should
immediately be cleaned and dried. Failure to do
so can create a slippery surface resulting in
falling/impact injury or death.
6. Make sure the red gasket is positioned
between the elbow and drain tube where they
join, slide retaining clamp over red gasket with
position nut at bottom of drain line and tighten.
L22-392 R1 31