201
show poe status
Description:
Show per PoE port information
Command Level
Global Configuration
Syntax:
show poe status [<port-list>]
Parameters:
<port-list> specifies the ports to be set. If not entered, all ports are set.
Example 1:
Switch(config)# show poe status 1
Port Admin Oper
Power
Mode
Priority Power Limit[W]
Current Consumption
[W]
Current[mA]
Device
Class
Port1 Enable on 802.3at Low 15.4 13.4 279 0
Example 2:
Switch(config)# show poe status
Port Admin Oper
Power
Mode
Priority Power Limit[W]
Current
Consumption [W]
Current
[mA]
Device
Class
Port1 Enable on 802.3at Low 15.4 13.4 279 0
Port2 Enable on 802.3at Low 15.4 11.3 236 0
Port3 Enable on 802.3at Low 15.4 6.5 135 3
Port4 Enable off 802.3at Low 15.4 0 0 0
Port5 Enable off 802.3at Low 15.4 0 0 0
Port6 Enable off 802.3at Low 15.4 0 0 0
Port7 Enable off 802.3at Low 15.4 0 0 0
Port8 Enable off 802.3at Low 15.4
0
0
0