CHASSIS/BRAKES/FINAL DRIVE
5.9
Brake Bleeding - System Rebuild
Brake Bleeding - Fluid Change, Cont.
13. Field test machine before putting into service. Check for proper braking action and lever reserve. With lever
firmly applied, lever reserve should be no less than 1/2s (1.3 cm) from handlebar.
14. Check brake system for fluid leaks.
Hydraulic Brake
Brake Lever Reserve Limit
Not less than 1/2s (1.3 cm)