Special information tone (SIT) is generated from a set of frequency components:
First frequency: 985 Hz at -16 dBm
Second frequency: 1428 Hz at -16 dBm
Third frequency: 1777 Hz at -16 dBm
The expiration time is exactly 20 seconds. It has only one cadence segment, which includes 4 on-off
sections. The segment has infinite repeating time:
The first on-off section: generated by the first frequency component, and it has 0.38 tone second
active time and 0 inactive time.
The second on-off section: generated by the second frequency component, and it has 0.38 tone
second active time and 0 inactive time.
The third on-off section: generated by the third frequency component, and it has 0.38 tone second
active time and 0 inactive time.
The fourth on-off section: only generate silence since no frequency component is specified. It has
tone 0 second active time and 4 seconds inactive time.
Stutter Tone
STUTTER, "350-18,440-18;20;.2(.1+.1);()"
Stutter dial tone is generated from a mixture of two frequency components:
350 Hz at -18 dBm and 440 Hz at -18 dBm. The expiration time for the entire tone is exactly 20
seconds. It has two cadence segments.
The first segment includes only one on-off sections, on 0.1 second and off 0.1 second, and on-off
repeats for 2 seconds.
The second segment includes one on-off section, and has infinite repeating time and infinite tone
active time, and plays until the entire tone duration has elapsed.
For more information on Tone Profile A & B parameters, see the Tone Profile A & B Parameter Guide
table in the Parameter Reference Guide.
Ring Profile A & B
Ring Profile Features
[field-1];[field-2];...;[field - 5]
Use a semicolon to separate as many as five configuration fields.
Note that no spaces are allowed to be used in a tone profile pattern.
Ring Field-1 Composition
Field-1 describes the overall ringing duration in seconds.
The expression is a numeric value, and supports as many as 3 decimated digits.
94
Chapter 14Appendix A

Table of Contents

Other manuals for Poly ATA 400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Poly ATA 400 Series and is the answer not in the manual?

Poly ATA 400 Series Specifications

General IconGeneral
BrandPoly
ModelATA 400 Series
CategoryAdapter
LanguageEnglish

Related product manuals