MAX™ Operator Manual
©
Original Printed In English
SECTION 6 - FAULT & ALERT MANAGE-
6-6
Batch Count Is Completed The Batch Counter actual value has
reached the Target Count. This alert
will not interrupt the bagger cycle,
but subsequent cycles are not possi-
ble until the Alert has been reset.
Batch is done. Reset and bagger is
free to cycle again.
Factory Setting Saved The current bagger settings and
options have been backed up to the
PLC Data Table.
This is simply an alert to let the user
know that the settings have been
successfully saved. The message
can be cleared by pressing the Re-
set button, or it will automatically
clear on the next bagger cycle.
Waiting For Filler The bagger has signaled the Filler
machine that it is read to accept pro-
duce and is waiting for the Filler to
trigger the next bagger cycle.
Filler must complete the delivery of
product and torn on the Filler Trig-
ger Input.
Recovery Mode Bag Open Retry The bagger Funnel Door is cycling
and retrying to open the original
bag.
No action is required.
Recovery Mode Feeding New Bag The bagger is feeding out a replace-
ment bag. It could not open the orig-
inal bag.
No action is required.
Cycle Bagger To Activate Filler The bagger is in Filler Mode. The
operator must cycle out the first bag
to activate the Filler cycle.
Cycle Start is required by operator.
This can be done from the HMI,
Foot Switch, etc.
Bag Is Filled A bag has been filled and sealed in
Filler Mode.
No action is required.
ALERT
CAUSE SOLUTION