Adjustments and Tests
149
12. Press >: The current phase index displays. Press > again: An asterisk (*)
appears next to the phase value.
13. Press
< to increase or ; to decrease the phasing index value, then press
ENTER to activate the value as it prints. Continue to increase or decrease
the phasing index until the pattern of H’s is acceptable.
14. Press
= twice: “Printer Tests / Phase Printer” displays.
15. Press ENTER to stop the test.
16. Press CLEAR. “OFFLINE / CONFIG. CONTROL” displays.
17. Press
= + > (or the key combination set by the user). “ENTER SWITCH
LOCKED” briefly displays.
18. Close the printer cover.
19. Press the ON LINE key to place the printer on-line.
NOTE: If you changed the phasing value, power down the printer, remove
the shuttle cover, and write the new phase value on the aluminum
shuttle casting.