br Battery Reconditioning Schedule.
sc Spare Drive Check Schedule.
-i <RC scheduler id> Species the RC scheduler ID. It’s used for list/modify/delete RC
scheduler. If the option is not specied, assumed to all.
-s “<option>=<value>” Used to specify which BGA scheduler settings to change.
status= Species status type of scheduler.
enable Enable a scheduler.
disable Disable a scheduler. The default is disable.
starttime= Used to specify start time of scheduler in the following format hh:mm
where hour’s range is 0-23, minute’s range are 0-59.
The default is 20:00 for MP, 22:00 for RC and SC, 02:00 for others.
recurtype= Species recurrence type of scheduler.
The default is monthly for br type, weekly for others.
daily
weekly
monthly
recurInterval= Species recurrence Interval.
This option is for Daily and Weekly recurrence type.
For Daily type, the range is 1-255.
For Weekly type, the range is 1-52.
For Daily type, the default is 1.
For Weekly type, the default is 4 for MP, 2 for RC, 1 for others.
dow= Day of Week. This is for Weekly or Monthly recurrence type scheduler.
Regarding Monthly type, if daypattern (see below) is
192
Promise Technology
Vess R3600 / Vess J3600 Product Manual