factorydefaults
Usage
factorydefaults -a <action> -t <type>
Summary
The factorydefaults command restores specied settings to the factory default values.
Options
-a <action> Species the action to perform.
restore Restore the factory default settings.
erase Erase iSCSI congurations(used along with <-t iscsi>).
-t <type> Species the type of settings to restore.
all All settings.
allfw All rmware settings.
allsw Subsystems only. All software settings.
The following are individual Firmware settings:
bga Background activity settings.
ctrl Controller settings.
encl Enclosure settings, including temperature thresholds, buzzer, etc.
fc fc port settings. Fibre Channel host interface product only.
iscsi iSCSI settings, restore operation applies to port and iSNS; erase
operation applies to all iSCSI components, including target, portal, chap,
trunk, etc. iSCSI host interface product only.