5-22
VIBXPERT II 05.2012
Measurement tasks
Multi-measurement task in the 'Multimode' operating mode
Multi-measurement tasks are created in the Task Manager:
• OpentheTaskManager(seeP.3-19).
• Selecttheuppermenu'Measurement task' and press the MENU
key.
• Clickon'New'andenteranameforthenewmeasurementtask.
• Inthe'Startmeasurement'eld,denewhetherthemeasurements
shouldbestartedconsecutivelyorsimultaneously.Withthe'Syn-
chronous' setting, you can additionally define a trigger channel
('Synchronous+Channel...').
The measurement task, sensors and trigger parameters can be set up
in the respective tabs:
task taB
Hereyoucansetthesensorforeachchannel(A/B),anddenewheth-
er the rpm should be recorded as well.
channel a / channel B taB
Hereyoucandenethemeasurementtaskforeachchannel:
• Press the MENU key and click on 'Select task' (see below). The
import wizard appears, in which you can select the individual
measurement tasks in three steps (see also the next section, 'Dual
measurement').
trigger taB
The trigger settings only apply when the multi-measurement task is
tostartwithatrigger(see'Startmeasurement'above).Therstmea-
surement starts as soon as the Trigger level is exceeded and the Trigger
start time haselapsed(seealsop.3-22).Thetriggerlevelsrelatesto
the measurement range.
Multitask (Multimode)
Selecting individual meas. tasks (left)
Setting the trigger parameters (right)
Measurement task
Evaluation setup