EasyManua.ls Logo

Pulseroller ConveyLinx-Ai2 - Page 131

Pulseroller ConveyLinx-Ai2
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inter Module Communication Time
The Inter Module Communication Time value is used to adjust the behavior of the Flex Zone operation. In
situations where carton lengths can be close to the length of the zones (i.e. distance between photoeyes),
you may want to adjust Flex Zone operation so that it either engages or not in these situations.
Typically there are one or two driven rollers past the sensor in a Zone. If you have cartons
that encroach upon these rollers when accumulated in the downstream zone, you may
want Flex Zone to engage so that the next upstream carton will not enter the zone (Zone
A in the example), thus not running these rollers underneath the accumulated carton.
PULSEROLLER ConveyLinx-Ai2 User's Guide - 1.7
Page 129 of 154

Table of Contents

Other manuals for Pulseroller ConveyLinx-Ai2