7.1.3.1.2. Train Release
All 3 Cartons are Accumulated
When Carton 1 releases – Cartons 2
and 3 also release at the same time
Select Train from the pull-down box for
Train Mode
Last modified: Aug 18, 2020
Please note that starting many zones in Train Release mode particularly with heavy loads
can cause voltage drops on your power supplies. Be sure to take care in sizing your power
supply needs. You should consider GAP Train Release Mode if power supply sizing is a
concern
!