EasyManua.ls Logo

Pulseroller ConveyLinx-Ai2 - Most Upstream Zone

Pulseroller ConveyLinx-Ai2
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.2.9.2. Most Upstream Zone
By default and without any intervention, the most upstream zone will never turn on to accept new product.
To cause the most upstream zone to run to accept an item with a wired signal, you need to utilize the Aux I/
O Pin 2 for the upstream zone as a Wake-up input.
Assuming the most upstream zone is
connected to the left side of the module;
we set the Left Pin 2 to Wake up from the
drop-down box and make sure we click
the UP arrow to indicate that the Left Pin
2 signal is to be associated with the
Upstream Zone. When the Left Pin 2
signal is energized, the upstream zone
will run to accept an item
Last modified: Aug 18, 2020
PULSEROLLER ConveyLinx-Ai2 User's Guide - 1.7
Page 138 of 154

Table of Contents

Other manuals for Pulseroller ConveyLinx-Ai2