EasyManua.ls Logo

Quantronix CubiScan 110 - Read Inactivity Timeout

Default Icon
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TCP/IP Communications Setup Command Set Communications Protocol
80 CubiScan 110
Read Inactivity Timeout
This command is used to read the current inactivity timeout setting
from the CubiScan 100L.
Pos Len Description Type Range ASCII
1 1 Start of Text Control (STX) 02h
2 1 Read Command Alpha (~) 7Eh
3 1 Timeout Command Alpha (T) 54h
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Read Command Alpha (~) 7Eh
3 1 Timeout Command Alpha (T) 54h
4 1 Acknowledge Alpha (A) 41h
5 3 Value in Minutes Alpha (001-255)
6 1 End of Text Control (ETX) 03h
7 1 Carriage Return Control (CR) 0Dh
8 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Read Command Alpha (~) 7Eh
3 1 Timeout Command Alpha (T) 54h
4 1 Neg. Acknowledge Alpha (N) 4Eh
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah

Table of Contents