TCP/IP Communications Setup Command Set Communications Protocol
80 CubiScan 110
Read Inactivity Timeout
This command is used to read the current inactivity timeout setting
from the CubiScan 100L.
Pos Len Description Type Range ASCII
1 1 Start of Text Control (STX) 02h
2 1 Read Command Alpha (~) 7Eh
3 1 Timeout Command Alpha (T) 54h
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Read Command Alpha (~) 7Eh
3 1 Timeout Command Alpha (T) 54h
4 1 Acknowledge Alpha (A) 41h
5 3 Value in Minutes Alpha (001-255)
6 1 End of Text Control (ETX) 03h
7 1 Carriage Return Control (CR) 0Dh
8 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Read Command Alpha (~) 7Eh
3 1 Timeout Command Alpha (T) 54h
4 1 Neg. Acknowledge Alpha (N) 4Eh
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah