Troubleshooting Control Panel Error Messages
CubiScan 110 47
3. The sensor may be defective. Replace the sensor or contact
Quantronix.
Weight If timeout error 01 appears in the WEIGHT window, it indicates that
no communication is taking place between the load cell and the con-
troller. Consider the following.
1. Verify that the load cell connector has not been disconnected.
2. The load cell or its cabling may be defective or damaged.
Inspect and replace the load cell if suspect, or contact Quan-
tronix.
Other Error Codes
If any of the following error codes appear in any display window on
the control panel repeatedly, make note of the error code and contact
Quantronix for assistance.
-02- Zero error
-03- Load cell dead weight
-04- Load cell weight total
-05- Load cell dead weight query
-06- Load cell weight total query
-07- Load cell dead weight set
-08- Load cell weight total set
-09- Tare
-10- Transmit device data
-11- Calibrate
-12- Measure signal value
-13- Configure output format
-14- Internal analog to digital rate
-15- Amplifier signal filter
-16- Amplifier signal selection
-17- Corrective function switch
-18- Automatic calibration switch
-19- Restart