Communications Protocol CubiScan 110 Command Set
CubiScan 110 57
Location Id/City Code
This command is used to set the CubiScan location identification.
This data is stored in permanent memory and need only be set once
for each CubiScan 110.
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Pos Len Description Type Range ASCII
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Location Id. Command Alpha (L) 4Ch
3 6 City Code Alpha 000000-ZZZZZ
9 1 End of Text Control (ETX) 03h
10 1 Carriage Return Control (CR) 0Dh
11 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Location Id. Command Alpha (L) 4Ch
3 1 Acknowledge Alpha (A) 41h
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Location Id. Command Alpha (L) 4Ch
3 1 Neg. Acknowledge Alpha (N) 4Eh