No Response When You Turn Power On Troubleshooting
44 CubiScan 110
No Response When You Turn Power On
If there is no response when you power on the CubiScan 110, do the
following:
1. Verify that the power strip is “live” and that the AC power cord
is properly and securely connected to the power strip.
2. Verify that the power cord is securely connected to the power
connector on the back of the CubiScan.
Readings Are Not Accurate
If you suspect that the CubiScan 110 readings are inaccurate, do the
following:
1. Zero the scale by making sure the platform is free of all objects
and then selecting
Zero from the toolbar or Tools menu in Qbit.
(If a computer is not connected, press
<zero> on the control
panel.)
If the CubiScan does not return to zero or is slow to return to
zero, level the CubiScan and make certain that all five leveling
legs are resting on the supporting surface. Refer to “Placement
and Leveling” on page 13 for more information.
2. Recalibrate the CubiScan. Refer to Chapter 4 “Calibration” on
page 27 for instructions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantronix CubiScan 110 and is the answer not in the manual?

Quantronix CubiScan 110 Specifications

General IconGeneral
BrandQuantronix
ModelCubiScan 110
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals