TCP/IP Communications Setup Command Set Communications Protocol
76 CubiScan 110
Set Gateway Address
This command is used to set the network gateway address on the
CubiScan 110. It can be the address of a network server or router
and is expressed in “dot” notation. Consult your network adminis-
trator to obtain the network gateway address.
5
7-15
or n
Subnet Address Alpha
(0.0.0.0) to
(255.255.255.255)
5+n 1 End of Text Control (ETX) 03h
6+n 1 Carriage Return Control (CR) 0Dh
7+n 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Read Command Alpha (~) 7Eh
3 1 Subnet Address Command Alpha (N) 4Eh
4 1 Neg. Acknowledge Alpha (N) 4Eh
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah
Pos Len Description Type Range ASCII
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
3 1 Gateway Address Command Alpha (G) 47h
4
7-15
or n
Gateway Address Alpha
(0.0.0.0) to
(255.255.255.255)
4+n 1 End of Text Control (ETX) 03h
5+n 1 Carriage Return Control (CR) 0Dh

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantronix CubiScan 110 and is the answer not in the manual?

Quantronix CubiScan 110 Specifications

General IconGeneral
BrandQuantronix
ModelCubiScan 110
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals