CubiScan 110 Command Set Communications Protocol
62 CubiScan 110
Units
This command causes the CubiScan to report its current modes of
operation.
3 1 End of Text Control (ETX) 03h
4 1 Carriage Return Control (CR) 0Dh
5 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Self Test Command Alpha (T) 54h
3 1 Acknowledge Alpha (A) 41h
4 2 Identifier Numeric (00-99)
6 1 End of Text Control (ETX) 03h
7 1 Carriage Return Control (CR) 0Dh
8 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Self Test Command Alpha (T) 54h
3 1 Neg. Acknowledge Alpha (N) 4Eh
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Pos Len Description Type Range ASCII
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Values Command Alpha (U) 55h
3 1 End of Text Control (ETX) 03h