Communications Protocol CubiScan 110 Command Set
CubiScan 110 63
4 1 Carriage Return Control (CR) 0Dh
5 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Units Command Alpha (U) 55h
3 1 Acknowledge Alpha (A) 41h
4 1 Dimension Units Alpha (E/M) 45h or 4Dh
5 1 Weight Units Alpha (E/M 45h or 4Dh
6 1 Factor Units Alpha (D/I) 44h or 49h
7 4 Dimensional Factor Numeric 0000-9999
11 6 Location Id./City Code Alpha 000000-ZZZZZZ
17 1 End of Text Control (ETX) 03h
18 1 Carriage Return Control (CR) 0Dh
19 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Units Command Alpha (U) 55h
3 1 Neg. Acknowledge Alpha (N) 4Eh
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Pos Len Description Type Range ASCII