QLS-4100 Xe F-3
13 Bar-code check digit error
The selection for enabling the bar-code check digit is faulty.
15 Bar-code interpretation width error
The range for width values is the same as for height values.
16 Bar-code interpretation height error
Valid settings for font height are 10 to 2000 for TrueType® fonts.
17 Bar-code interpretation font selection error
The font parameter of a Define Bar-code Symbol command
(<STX>BFn,...,i,...) is invalid.
18 Alphanumeric write method error
The AF command contains an invalid “write method” parameter
(must be “1”).
20 Format command error
The structure of one or more label format commands is faulty. Some
examples would be:
misplaced or missing delimiter
invalid characters in the command string (e.g., <STX>FQ...)
missing or faulty line termination (<lf><cr> rather than <cr><lf>)
21 Numeric value error
A numeric value in a format string is invalid. If a non-numeric string
is placed where the printer expects a numeric string, this error will
occur.
30 Label length error
The length parameter of the Set Label Length command is out of
range.
31 Batch count error
Acceptable batch count range is 1 to 100000.
32 Group count error
Acceptable group count range is 0 to 100000.
33 Serial copies error
Acceptable serial copies range is 1 to 100000.
35 Box width error
The width value of a graphics field is invalid.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QuickLabel Systems QLS-4100 and is the answer not in the manual?

QuickLabel Systems QLS-4100 Specifications

General IconGeneral
BrandQuickLabel Systems
ModelQLS-4100
CategoryLabel Maker
LanguageEnglish

Related product manuals