13
5.4. Inputs / Outputs
Standard PUE HY10 indicator is equipped with 4 optoisolated inputs and 4
semiconductor outputs (semiconductor relays). Signals are sent via M12 8P
connectors.
4OUTPUTS
Pin1 – OUT1
Pin2 – OUT2
Pin3 – OUT3
Pin4 – OUT4
Pin5 – COM
Pin6 – 24VDC
Pin7 – GND
Pin8 – NC
4INPUTS
Pin1 – IN1
Pin2 – IN2
Pin3 – IN3
Pin4 – IN4
Pin5 – COM
Pin6 – 24VDC
Pin7 – GND
Pin8 – NC
5.4.1. Technical Specifications
Output parameters
Output quantity 4
Output type Solid-state relay
Cable cross-section 0.14 - 0.5mm
2
Maximum output current 0.5A DC
Maximum output voltage 30VDC, AC
Input parameters
Input quantity 4
Input type Optoisolated
Cable cross-section 0.14 - 0.5mm
2
Voltage range 5 - 24VDC

Table of Contents