6. Touch the Fore/Aft offset value and use the on-screen keypad to enter the distance of the section midpoint
from the GPS antenna. If the section is behind the GPS antenna, enter a negative value for the Fore/Aft
offset value.
7. Touch Next to advance to the next boom or implement section to the right or Prev to go back to the
previous section to the left.
8. Once the width and offset values are entered correctly for each boom or implement section, touch the OK
button to return to the Boom Setup Summary screen.
9. Verify that the section configuration overview represents the actual application equipment or implement
configuration.
10. Touch OK to save the section settings and return to the Viper Pro main screen.