Appendix C
268 OmniSeed™ Viper Pro™ Installation & Operation Manual
6. Note the ‘Ttl Vol’ (total volume) column and the registered values for each control channel.
7. Toggle the section switches and the master switch on.
8. With a small jumper wire (or paper clip), short between the 2 o’clock and 6 o’clock sockets with a ‘short-no-
short’ motion. Each time contact is made, the total volume should increase by increments of 1 or more.
9. If the total volume does not increase, remove the section of cable and repeat the test at the connector that
is the next closest to the node. Replace the defective cable as required.
10. Verify the pin connection and voltage from the previous chart.
11. If all of the cables test ‘good, replace the flow meter.
Note: After testing is complete, re-enter the correct meter cal before starting application.