SP Tables
M047 3-38 SM Appendix
5816 003
Function Flag
Enables or disables the remote service function.
[0 to 1 / 0 / 1 /step]
0: Disabled
1: Enabled
5816 007
SSL Disable
Uses or does not use the RCG certification by SSL when calling the RCG.
[0 to 1 / 0 / 1 /step]
0: Uses the RCG certification
1: Does no use the RCG certification
5816 008
RCG Connect T/O
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 30 / 1 second /step]
5816 009
RCG Write Timeout
Specifies the write timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
5816 010
RCG Read Timeout
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
5816 011
Port 80 -
Enables/disables access via port 80 to the SOAP method.
[0 or 1 / 0 / – ]
0: Disabled
1: Enabled