24 Rockwell Automation Publication 2713P-UM001G-EN-P - May 2022
Chapter 2
Panel Guidelines
The terminals are panel-mounted devices that mount in the door or wall of a
NEMA, UL Type, or IP rated enclosure:
• Enclosure panels must meet the panel thickness requirements in Table 10
on page 26.
• The material strength and stiffness of the panel must be sufficient to hold
the terminal and maintain an appropriate seal against water and dust.
• The panel surface must be flat and free of imperfections to maintain an
adequate seal and NEMA, UL Type, or IP ratings.
Panel Cutout Dimensions
Use the template that is shipped with your terminal to mark the cutout
dimensions.
PanelView 5310 - Panel Cutout Dimensions
Terminal
Size (in.) Input Type
Height,
mm (in.)
Width,
mm (in.)
6 Touch 123 (4.84) 156 (6.14)
7 150 (5.9) 210 (8.25)
9 162 (6.38) 252 (9.92)
10.4 224 (8.82) 269 (10.59)
12.1 218 (8.58) 312 (12.28)