EasyManua.ls Logo

Rockwell Automation SMC Dialog Plus

Rockwell Automation SMC Dialog Plus
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-16
Product Overview
Slow Speed with Braking Option
The Slow Speed with Braking option provides a jog speed for process
set-up and braking-to-stop at the end of the cycle.
Figure 1.17 Slow Speed with Braking Option
Motor
Speed
100%
Start
Run Slow
Speed
Braking
7% or 15%
Stop
Coast-to-rest
Time (seconds)
!
ATTENTION: Accu-Stop and Slow Speed with
Braking are not intended to be used as an emergency
stop. Refer to applicable standards for emergency stop
requirements.

Table of Contents

Related product manuals