Effectivity: 914 Series
Edition 2 / Rev. 0
d04277
page 47
July 01/2008
BRP-Rotax
INSTALLATION MANUAL
The measuring of the coolant exit temperature is performed using a separate
sensor, which has to be installed in the line between expansion tank (1) and
radiator inlet (2).
Fig. 17
09152
The sensor may be installed in a „TEE“ inline with the fluid hose or the
expansion tank may be modified to attach the sensor (not supplied by BRP-
Rotax).
WARNING: Do not restrict the coolant flow with the sensor devise.
CAUTION: It is possible to receive a misleading reading when measuring
fluid temperatures. If fluid volume is lost and the probe is not
fully submerged in the fluid the display could show a lower
temperature than actual (measuring air temperature instead
of fluid temperature).
2
1

Table of Contents

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm

Related product manuals