page 92
July 01/2008
Effectivity: 914 Series
Edition 2 / Rev. 0
d04280
INSTALLATION MANUAL
BRP-Rotax
15.1.1) Drainage pipelines to airbox and trip tray
▲ WARNING: Connect drainage lines well, otherwise emerging fuel from a
possible leakage could drip onto the exhaust system. RISK
OF FIRE!
- The lines have to be routed such that in case of a damage the surplus fuel
is drained off suitably.
- Route the lines without kinks and avoid tight bends
- Route the lines with a continuous decline.
- The lines have to be protected against any kind of blockage e.g. by
formation of ice.
■ CAUTION: With closed or blocked leakage piping, fuel could end up on
exhaust system. RISK OF FIRE!
Connecting nipple (2) and (P2) for leakage line
outside dia. ø 6 mm (1/4")
slip on length max. 17 mm (11/16")
Fig. 54
08415
2
1
P2