Effectivity: 914 Series
Edition 2 / Rev. 0
d04278
page 79
July 01/2008
BRP-Rotax
INSTALLATION MANUAL
direction of rotation of engine
appropriate plug
pressure.....max. 1 bar
(15 psi)
05446
F
IN
OUT
05448
4
5
2
1
08413
back from
engine (2)
to oil pump (1)
7
6
3
max. 0,5 mm
(0,02 in.)
Fig. 45
Fig. 46
13.12)Replacement of components
If a malfunction of hydraulic valve tappet should be found during this check of priming
process, the relevant hydraulic valve tappet has to be replaced and the valve spring
support has to be inspected for wear.
All work has to be performed in accordance with the relevant Maintenance Manual.