Notes regarding too high air temperatures in the air box:
If in case of high intake air temperature the max. air temperature in the airbox is
frequently or permanently above the limit, the arrangement of air intake has to be
improved or an intercooler has to be installed.
NOTE: Intercooler is not in the supply volume.
Intercooler has to be installed between pressure side of turbo (2) and inlet (3)
into airbox.
16.2.2) Requirements on the intercooler:
- a minimum flow rate of 300 m
3
/h (390 yd
3
/h) has to be warranted for all
conditions
- the pressure loss must not exceed 15 hPa
CAUTION: No additional forces or moments are allowed on turbo charger
or airbox, therefore the intercooler has be supported inde-
pendent and free of vibrations.
Ladeluftkühler
(Intercooler)
Fig. 59
08416
3
2
1

Table of Contents

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm

Related product manuals