14.2) Operating limits
WARNING: Design and layout of the fuel system has to warrant engine operation
within the specified limits.
Fuel pressure:
max. .........................................................airbox pressure + 0,35 bar (5 p.s.i.)
min. ..........................................................airbox pressure + 0,15 bar (2,2 p.s.i.)
nominal. .....................................................airbox pressure + 0,25 bar (3,6 p.s.i.)
The fuel pressure of the electric fuel pump must not exceed the manifold pressure by
more than 0,35 bar (5 p.s.i.)
WARNING: Fuel pressure in excess of stated limit can lead to an override of the
float valve with subsequent engine stop.
NOTE: On the standard engine no connection is provided for measuring the
fuel pressure. See section 14.5.

Table of Contents

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm