1.2 Description of function
Device components The device consists of a monitor and a measuring mat.
The monitor is for administering patient and user data and for preparing and
evaluating bioimpedance measurements. The device is equipped with a
touchscreen display.
The monitor has a storage compartment with a magnetic catch for storing the
measuring mat.
The measuring mat is placed on the patient's legs for a bioimpedance mea-
surement. Measured results are transmitted to the monitor unit by WiFi. The
electrode cables of the measuring mat are equipped with connections for
push-button electrodes.
Power supply The monitor is powered by a connection to the electricity supply. The monitor
has a lithium-ion rechargeable battery to provide a mobile power supply.
The measuring mat is powered by a lithium-ion rechargeable battery. The
rechargeable battery is charged by an inductive charging interface in the stor-
age compartment of the monitor.
Bioimpedance measurement The bioimpedance measurement is carried out with the patient lying down,
using the 8-point method. The 4-point method (measuring the right half of
the body) is likewise possible. The low alternating current is provided and
impedance is measured by the electrode cables of the measuring mat. The
electrode cables are connected to two pairs of electrodes for each half of the
body. The electrodes are affixed to the patient's hands and feet.
Recording weight and height Scales and length measuring devices from the seca 360° wireless system can
transmit measured results to the device wirelessly. Alternatively, the patient's
weight and height can be recorded manually.
Administration of user accounts User accounts can be set up and administered directly on the device. The
user accounts for the device can be synchronized automatically with the user
accounts of the seca analytics 115 PC software. This allows access to both
the device and the PC software with the same user account.
Device components
Power supply
Bioimpedance measurement
Recording weight and height
Administration of user accounts
Administration of seca patient files
Evaluating measured results
Data transmission and network functions
Compatibility