GB SGM Technology for lighting
User’s Manual 1.00 Pi
lot 3000
- 80 -
6.2 The Cues Timing
Pilot 3000 manages the Cues timing accordingly to the necessities and obviously to the type of Playback.
We will analyse Pilot 3000 timing of Cues activated in the Normal and Live! Modes and in the Chase mode.
TIMING NORMAL – LIVE!
By default, every time you store a Cue, Pilot 3000 automatically assign a set of four times to ALL the
Attributes involved by the Cue itself. The times are:
“Delay”
“Fade IN”
“Wait”
“Fade OUT”
T
he default times values are:
0 seconds for the Delay time
2 seconds for the Fade IN time
Wait time not assigned (same as Delay time)
Fade OUT not assigned (same as Fade IN time)
Each operator can change the Default times for each Show through the m nu:
SETUP -> Option -> Default Delay Time
SETUP -> Option -> Default FadeIn Time
The “Wait” e “Fade-OU T” times aren’t normally assigned f r default and, in case you want to introduce
them, they will consequently modify the Cue’s behavior d ring the Playback.
We will see here below as these times act during the P ayback.