MX-3114N SIMULATION 6 – 46
Code descriptions
List of destination groups
AT HI_WARMUP_BORDER
Threshold value alpha when alpha ï‚°C or
above
1 - 119
70 70 70 70 70 70
AU LO_WU_JOB_SET_TMP
Job enable TH_UM temperature when warm
up at alpha ï‚°C or below
70 - 230 155 160 165 160 165 170
AV JOBEND_FUMON_TIME
Fusing motor after rotation time after
completion of a job (excluding heavy paper,
OHP and envelope)
0 - 255
555555
AW
LO_WU_JOB_SET_TMP_B
W
Job enable temperature (B/W) when the
upper roller temperature is lower than alpha
ï‚°C
70 - 230 155 160 165 160 165 170
Item/Display Content Setting
value
Default value (SW-A) Default value (SW-B)
Group
A
Group
B
Group
C
Group
A
Group
B
Group
C
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_LM Fusing thermistor main (Back surface of paper) HL_LM Heater lamp main (Heat roller for front surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
SW-A Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group Destination
Group AJAPAN–––––
Group B U. S. A CANADA INCH – – –
Group C EUROPE U. K AUS. AB_A AB_B CHINA