EasyManuals Logo

Shihlin electric SF-GT Series User Manual

Shihlin electric SF-GT Series
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
Appendix 1 Parameter Table
Parameter Table
200
Parameter
Number
Name Setting Range
Minimum
Setting
Unit
Default Value
User
Setting
Value
Reference
Page
P.58
Restart cushion time
0~60s 0.1s
5s
(7.5kW or
bel
ow)
P109
10s
(11kW~55kW
)
20s
(75kW or
above)
P.59
Reserved
P.60
Input signal filter constant
0~2047
1
31
P111
P.61
Remote setting function
selection
0~3 1 0 P111
P.62
Zero current detection level
0~200%, 99999
0.1%
5%
P113
P.63
Zero current detection time
0.05~1s, 99999 0.01s 0.5s P113
P.64
AM1 output terminal
selection
0~3 1 0 P105
P.65
Retry selection
0~4
1
0
P114
P.66
Stall prevention operation
reduction starting frequency
0~650Hz 0.01Hz
50Hz/60Hz
(note2)
P67
P.67
Number of retries at alarm
occurrence
0~10 1 0 P114
P.68
Retry waiting time
0~360s
0.1s
1s
P114
P.69
Retr
y accumulation time at
alarm
0 0 0 P114
P.70
Special regenerative brake
duty
0~60% 0.1% 0 P73
P.71
Idling braking and linear
braking selection
0, 1 1 1 P116
P.72
Carrier frequency
3.7kW or
below:1~15 kHz
1kHz
7.5kW or below:5
kHz
P116
5.5~7.5kW:1~10
kHz
11~22kW5 kHz
11~22kW :1~9 kHz
30~90kW4 kHz
30~90kW :1~9
kHz
110kW2 kHz
110kW :1~9 kHz
P.73
The selection of voltage
signal across terminal 2
-5
0~5 1 0 P97

Table of Contents