Appendix 1 Parameter Table
Number
Name Setting Range
Setting
Default Value
Page
P.39
The maximum operation
frequency (the target frequency
is set by the input signal of
1~650Hz 0.01Hz
50Hz/60Hz
(Note 2)
P99
P.40
Multi-function output terminal
SO1-SE function selection
0~10,16~19 1 1 P102
P.41 Up-to-frequency sensitivity 0~100% 0.1% 10% P104
P.42
Output frequency detection for
forward rotation
0~650Hz 0.01Hz 6Hz P104
P.43
Output frequency detection for
reverse rotation
0~650Hz,
99999
0.01Hz 99999 P104
P.44 The second acceleration time
0~3600s,
0.01s/0.1s
99999 P60
P.45 The second deceleration time
0~360s/
0~3600s,
99999
0.01s/0.1s
99999 P60
P.47 The second base frequency
0~650Hz,
0.01Hz 99999 P58
P.49 Stop bit length 0, 1 1 0 P74
P.51 CR & LF selection 1, 2 1 1 P74
P.52
Number of communication
0~10 1 1 P74
P.53
Communication check time
interval
0~999.8s,
99999
0.1s 99999 P74
P.54
AM1/HDO terminal function
0~5 1 0 P105
P.55 Frequency display reference 0~650Hz 0.01Hz
50Hz/60Hz
P105
P.56 Current monitoring reference 0~500A 0.01A
Rated output
current
P105
P.57 Restart coasting time 0~30s, 99999 0.1s 99999 P109