MTP-200 Series Users Manual
Shineway Technologies, Inc. - 50 -
Fig. 11.2 Events options
As to every event in the even sheet, display follows info:
Type: Different indicator used for different event type instruction. As to the
detailed indicator instruction, please refer to the paragraphs previous.
Number: Event number(one continuous number designated by OTDR application
program).
Position: Distance between OTDR and event or event and starting point of optical
fiber link.
Insert Loss: The loss of every event by unit of dB( calculated by application
program).
Reflection value: Calculated value for each event.
Attenuation: The attenuation for each optical fiber length(loss/distance).
Accumulation: The accumulating loss from the link starting point to the end of the
link.
Accumulating loss calculates the events listed in the event sheet and doesn’t calculate the
hidden events. About the more accurate link loss, please refer to the loss result displayed in
{Markers}.
11.14.1 Display the Event on the Trace and Locate Event In Even
Sheet
Through rolling the event sheet, user can check the relative info about all events tested on
the trace. When an event selected, there will be Markers appear on the trace which above the
event.
When the trace under magnification status, event and its Markers may not in the